Supply and install an A10/4HCT modular, axial toilet/bathroom/ shower-room fan as supplied by Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Bucks, HP12 3RH. The fan is to be suitable for installation either into a ceiling, wall or window, and be complete with an integral, adjustable, dynamic humidistat, an integral adjustable timer and have a pull-cord so that the fan can be operated manually as well as automatically via the humidistat. There should be a neon on the front of the fan to indicate manual control. The fan should be made of shockproof and heat resistant Plastic, contain a motor with sealed, self-lubricating bearings and be protected with a thermal cut-out The fan should be double insulated and be suitable for installation into Zones I and II. The fan is to be BEAB Approved and Marked, CE marked, and comply with current EC Low Voltage Directive EMC89/336 and with BSEN60529. The fan should finally comply with Building Regulations requirements for installation into a toilet/bathroom or shower-room.
Please note that these product properties are not a replacement for the manufacturer's literature and it is always recommended that Vectaire is consulted before specifying.
|
|
||
| Air Volume (?) | 320 m3/h | |
| Frequency (?) | 50 Hz | |
| Power (?) | 15 - 25 W | |
| Sound Level (?) | 43 dB | |
| Voltage (?) | 230 V | |
|
|
||
| Typical Use (?) | Bathrooms , Kitchens , Shower-rooms , Toilets , Utility Rooms | |
|
|
||
| Uniclass (?) | Pr_60_65 Air and fume source products | |