60-minute fire-rated cavity closer for eliminating damp and cold bridging around doors, windows, and sills.
Independently tested by Warrington Fire to achieve 60 minutes fire-rating and minimum 15 minutes insulation.
Suitable for cavities up to 150mm. Available in single profile for 50mm-100mm cavities and double profile for 105mm-150mm cavities. Cavity barriers for fully rebated / check reveal also available.
Compliant with Building Regulation Approved Documents C, B, L1 and L2 and satisfies BRE document Thermal Insulation: avoiding risks .
Fixing ties available in packs of 100.
Uses:
To close the cavity at external doors, window jambs and sills
To provide thermal insulation and prevent cold bridging
To provide a DPC at external doors, window jambs or sills
60 minutes fire rating and minimum 15 minutes insulation
Suitable for cavities up to 150mm
Suitable for masonry walls
Please note that these product properties are not a replacement for the manufacturer's literature and it is always recommended that Timloc Building Products is consulted before specifying.
|
|
||
| Fire Rated (?) | ||
| Fire Rating (?) | 60 minutes | 100% |
| Standards (?) | ISO 14001 , ISO 9001 , NHBC | |
|
|
||
| Uniclass (?) | Pr_35_90_50 Masonry walling ancillary products | |
|
|
||
| Product ID Number (?) | FR60/50 | |
| Quantity Per Pack (?) | 5 | |