ICS is a twin wall insulated chimney system for use on open and closed stoves, open fires, residential and small commercial multi fuel appliances, with continuous operating temperatures up to 450C and short firing up to 550C.
ICS is converted into ICS Plus by adding a lip seal to each component with a male form on the liner (see ICS Plus diagram below). This creates a twin wall insulated chimney system designed for the new generation of condensing gas and oil appliances, with continuous operating temperatures up to 200C, short firing up to 250C, and positive pressure up to 200pa at the appliance outlet.
For larger commercial and industrial applications of ICS in diameters 300mm to 700mm please refer to our separate sales brochure. For higher pressure applications up to 5000Pa e.g. generators, combustion and process equipment, please see the commercial brochure.
A multi-functional twin insulated venting system for use on a wide range of heating appliances, stand-by power engines, CHP and service ducting
Features
TECHNICAL SPECIFICATION
ICSICS PlusICS 5000
FuelGas, Oil, wood, coalGas, oilDiesel generators, gas, oil
Firing temp450C200C600C
Continuous Firing temp540C
Short Firing temp550C200C700C
Thermal Shock1000C1000C
Mode of OperationZero & negative pressurePositive pressurePositive, zero & negative pressure
Pressure Capabilities40Pa200Pa5000Pa (for higher pressure applications consult Rite-Vent Technical Department)
Fire Rating4 Hours Fire Rating to BS 476 Part 20
Outer Case304 : 1.4301 : X5CrNi 18-10
Outer Case Thickness0.6mm0.6mm (150 455mm dia.) 0.7mm (505 605mm dia.)
SeamLaser or inert gas welded
Liner316L : 1.4404 : X2CrNiMo 17-12-2
Liner Thickness (mm)0.5mm0.6mm
InsulationHigh performance mineral fibre
Insulation Thickness25mm (50, 75, 100 available)25mm
Average Thermal Resistance (200C)0.508m k/w
Dimensions
The dimension details are:
Int mm80100130150180200230250300
Ext mm130150180200230250280300350
APPLICATIONS
COMPONENTS & SYSTEMS
Typical installations of the ICS range will give you a brief overview of the components of the system.
Please note that these product properties are not a replacement for the manufacturer's literature and it is always recommended that Schiedel Chimney Systems Ltd is consulted before specifying.
|
|
||
| Uniclass (?) | Pr_70_65_30 Flues and chimneys | |